{"id":219,"date":"2018-01-26T10:53:28","date_gmt":"2018-01-26T01:53:28","guid":{"rendered":"http:\/\/www.mirapro.co.jp\/mpcweb\/?page_id=219"},"modified":"2020-11-16T17:47:05","modified_gmt":"2020-11-16T08:47:05","slug":"caution","status":"publish","type":"page","link":"https:\/\/www.mirapro.co.jp\/en\/list\/flexible-hose\/caution\/","title":{"rendered":"Precautions for sage handling"},"content":{"rendered":"<p class=\"page-title\">Flexible Hose  Precautions for safe handling<\/p>\n<ul class=\"inline-style caution_list margin-b\">\n<li>\n<p><img decoding=\"async\" src=\"http:\/\/www.mirapro.co.jp\/en\/wp-content\/uploads\/2018\/01\/caution_img01.jpg\" alt=\"\u30d5\u30ec\u30ad\u30b7\u30d6\u30eb\u30db\u30fc\u30b9 \u53d6\u308a\u6271\u3044\u4e0a\u306e\u6ce8\u610f \u66f2\u3052\u306a\u3044 \u306d\u3058\u3089\u306a\u3044\" class=\"alignnone size-full wp-image-220\" \/><\/p>\n<p class=\"page-text\"><span class=\"font-red\">Do not bend beyond minimum bending radius. <\/span><br \/>Hose can be locally damaged and that could lead to the performance deterioration.<\/p>\n<\/li>\n<li>\n<p><img decoding=\"async\" src=\"http:\/\/www.mirapro.co.jp\/en\/wp-content\/uploads\/2018\/01\/caution_img02.jpg\" alt=\"\u30d5\u30ec\u30ad\u30b7\u30d6\u30eb\u30db\u30fc\u30b9 \u53d6\u308a\u6271\u3044\u4e0a\u306e\u6ce8\u610f \u66f2\u3052\u306a\u3044 \u306d\u3058\u3089\u306a\u3044\" class=\"alignnone size-full wp-image-220\" \/><\/p>\n<p class=\"page-text\"><span class=\"font-red\">Do not bend around connection bracket. <\/span><br \/>In case you bend around connection bracket, make sure that  length as long as the hose OD is left straight.<\/p>\n<\/li>\n<li>\n<p><img decoding=\"async\" src=\"http:\/\/www.mirapro.co.jp\/en\/wp-content\/uploads\/2018\/01\/caution_img03.jpg\" alt=\"\u30d5\u30ec\u30ad\u30b7\u30d6\u30eb\u30db\u30fc\u30b9 \u53d6\u308a\u6271\u3044\u4e0a\u306e\u6ce8\u610f \u66f2\u3052\u306a\u3044 \u306d\u3058\u3089\u306a\u3044\" class=\"alignnone size-full wp-image-220\" \/><\/p>\n<p class=\"page-text\"><span class=\"font-red\">Do not twist hose<\/span><br \/>If you twist a hose, the hose can be locally damaged and that could lead to the performance deterioration.<\/p>\n<\/li>\n<\/ul>\n<p class=\"page-title2\">Hose with blade<\/p>\n<p class=\"margin-b\">Please do not shrink hose with blade. Blade and hose are manufactured in close contact in order to receive bulge of hose by pressure. If you shrink the hose, blade loosens to separate from hose. This could cause breakage of hose when applying internal pressure.<\/p>\n<p class=\"page-title2\">Hose with blade<\/p>\n<p class=\"page-text\">Please tighten up with the specified tightening torque. Because there is a possibility that malfunctions like below are caused, do not tighten up outside the scope of the specified tightening torque.<\/p>\n<p class=\"page-text\"><span class=\"font-red\">With not enough tightening torque.<\/span><br \/>\nIt may not be possible to obtain sufficient sealing performance.<br \/>\nBolt can come off due to vibration.<\/p>\n<p><span class=\"font-red\">With excessive tightening torque<\/span><br \/>\nGasket and O-ring can be damaged.<br \/>\nBolt can tear apart.<\/p>\n<p>List of recommended tightening torque<\/p>\n<div class=\"table-scroll\">\n<table class=\"f-h-inquiry_table caution_table\">\n<tr>\n<th>Code<\/th>\n<th>Nominal diameter of flange<\/th>\n<th>Bolt<\/th>\n<th>Recommended torque\uff08N\u30fbm\uff09<\/th>\n<\/tr>\n<tr>\n<td>MTJ-020<\/td>\n<td>VG20\/VF20<\/td>\n<td rowspan=\"4\">M8<\/td>\n<td rowspan=\"4\">9.8\uff5e14.7<\/td>\n<\/tr>\n<tr>\n<td>MTJ-025<\/td>\n<td>VG25\/VF25<\/td>\n<\/tr>\n<tr>\n<td>MTJ-040<\/td>\n<td>VG40\/VF40<\/td>\n<\/tr>\n<tr>\n<td>MTJ-050<\/td>\n<td>VG50\/VF50<\/td>\n<\/tr>\n<tr>\n<td>MTJ-065<\/td>\n<td>VG65\/VF65<\/td>\n<td rowspan=\"5\">M10<\/td>\n<td rowspan=\"5\">19.6\uff5e24.5<\/td>\n<\/tr>\n<tr>\n<td>MTJ-080<\/td>\n<td>VG80\/VF80<\/td>\n<\/tr>\n<tr>\n<td>MTJ-100<\/td>\n<td>VG100\/VF100<\/td>\n<\/tr>\n<tr>\n<td>MTJ-125<\/td>\n<td>210A<\/td>\n<\/tr>\n<tr>\n<td>MTJ-150<\/td>\n<td>235A<\/td>\n<\/tr>\n<tr>\n<td>MTC-034<\/td>\n<td>CF34<\/td>\n<td>M4<\/td>\n<td>2.0\uff5e3.0<\/td>\n<\/tr>\n<tr>\n<td>MTC-070<\/td>\n<td>CF70<\/td>\n<td>M6<\/td>\n<td>6.9\uff5e9.8<\/td>\n<\/tr>\n<tr>\n<td>MTC-114<\/td>\n<td>CF114<\/td>\n<td rowspan=\"2\">M8<\/td>\n<td rowspan=\"2\">9.8\uff5e14.7<\/td>\n<\/tr>\n<tr>\n<td>MTC-152<\/td>\n<td>CF152<\/td>\n<\/tr>\n<\/table>\n<p class=\"font-right page-text\">Recommended torque\uff08N\u30fbm\uff09<\/p>\n<\/div>\n<div class=\"margin-b\"><\/div>\n<p class=\"page-title2\">Hose with blade<\/p>\n<p class=\"page-text\">Please use O-ring\/Center Ring which is applicable to connection bracket. O-ring is not the attached part. If you need an attached part, please prepare by yourself or order with hose. <\/p>\n<p> O-ring correspondence table\uff08JIS VG flange\uff09<\/p>\n<div class=\"table-scroll\">\n<table class=\"f-h-inquiry_table caution_table centering\">\n<tr>\n<th>Code<\/th>\n<th>Nominal diameter(A)<\/th>\n<th>O-ring<\/th>\n<\/tr>\n<tr>\n<td>MTJ-020<\/td>\n<td>VG20<\/td>\n<td>V34<\/td>\n<\/tr>\n<tr>\n<td>MTJ-025<\/td>\n<td>VG25<\/td>\n<td>V40<\/td>\n<\/tr>\n<tr>\n<td>MTJ-040<\/td>\n<td>VG40<\/td>\n<td>V55<\/td>\n<\/tr>\n<tr>\n<td>MTJ-050<\/td>\n<td>VG50<\/td>\n<td>V70<\/td>\n<\/tr>\n<tr>\n<td>MTJ-065<\/td>\n<td>VG65<\/td>\n<td>V85<\/td>\n<\/tr>\n<tr>\n<td>MTJ-080<\/td>\n<td>VG80<\/td>\n<td>V100<\/td>\n<\/tr>\n<tr>\n<td>MTJ-100<\/td>\n<td>VG100<\/td>\n<td>V120<\/td>\n<\/tr>\n<tr>\n<td>MTJ-125<\/td>\n<td>VG125<\/td>\n<td>V150<\/td>\n<\/tr>\n<tr>\n<td>MTJ-150<\/td>\n<td>VG150<\/td>\n<td>V175<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"margin-b\"><\/div>\n<p>Center ring correspondence table\uff08ISO KF flange \uff09<\/p>\n<div class=\"table-scroll\">\n<table class=\"f-h-inquiry_table caution_table centering\">\n<tr>\n<th>Code<\/th>\n<th>Nominal diameter(A)<\/th>\n<th>Center ring<\/th>\n<\/tr>\n<tr>\n<td>MTK-010<\/td>\n<td>KF10<\/td>\n<td>MCK-2010<\/td>\n<\/tr>\n<tr>\n<td>MTK-016<\/td>\n<td>KF16<\/td>\n<td>MCK-2016<\/td>\n<\/tr>\n<tr>\n<td>MTK-025<\/td>\n<td>KF25<\/td>\n<td>MCK-2025<\/td>\n<\/tr>\n<tr>\n<td>MTK-040<\/td>\n<td>KF40<\/td>\n<td>MCK-2040<\/td>\n<\/tr>\n<tr>\n<td>MTK-050<\/td>\n<td>KF50<\/td>\n<td>MCK-2050<\/td>\n<\/tr>\n<tr>\n<td>MTK-080<\/td>\n<td>KF80<\/td>\n<td>MCK-2080<\/td>\n<\/tr>\n<tr>\n<td>MTK-100<\/td>\n<td>KF100<\/td>\n<td>MCK-2100<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"margin-b\"><\/div>\n<p class=\"page-title2\">Gasket<\/p>\n<p class=\"page-text\">Please use an O-ring that is applicable to connection bracket. O-ring is not the attached part. If you need an attached part, please prepare by yourself or order with hose.<\/p>\n<p>Gasket size correspondence table<\/p>\n<div class=\"table-scroll\">\n<table class=\"f-h-inquiry_table caution_table centering\">\n<tr>\n<th>CF flange<\/th>\n<th>Size (OD\u00d7ID)<\/th>\n<th>Material<\/th>\n<\/tr>\n<tr>\n<td>CF34<\/td>\n<td>21.3 x 16.3<\/td>\n<td rowspan=\"4\">Copper plate<br \/>\uff08Oxygen-free copper\uff09\n<\/td>\n<\/tr>\n<tr>\n<td>CF70<\/td>\n<td>48.1 x 36.9<\/td>\n<\/tr>\n<tr>\n<td>CF114<\/td>\n<td>82.4 x 63.7<\/td>\n<\/tr>\n<tr>\n<td>CF152<\/td>\n<td>120.5 x 101.8<\/td>\n<\/tr>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Flexible Hose Precautions for safe handling Do not bend beyond minimum bending radius. Hose can be locally dam [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":191,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-219","page","type-page","status-publish","hentry"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.mirapro.co.jp\/en\/wp-json\/wp\/v2\/pages\/219","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mirapro.co.jp\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mirapro.co.jp\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mirapro.co.jp\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mirapro.co.jp\/en\/wp-json\/wp\/v2\/comments?post=219"}],"version-history":[{"count":3,"href":"https:\/\/www.mirapro.co.jp\/en\/wp-json\/wp\/v2\/pages\/219\/revisions"}],"predecessor-version":[{"id":818,"href":"https:\/\/www.mirapro.co.jp\/en\/wp-json\/wp\/v2\/pages\/219\/revisions\/818"}],"up":[{"embeddable":true,"href":"https:\/\/www.mirapro.co.jp\/en\/wp-json\/wp\/v2\/pages\/191"}],"wp:attachment":[{"href":"https:\/\/www.mirapro.co.jp\/en\/wp-json\/wp\/v2\/media?parent=219"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}